Line 116: Line 116:  
*A<sub>i</sub> = Catchment impervious area (m<sup>2</sup>)
 
*A<sub>i</sub> = Catchment impervious area (m<sup>2</sup>)
 
*d<sub>p</sub>' = Design surface ponding depth (m)
 
*d<sub>p</sub>' = Design surface ponding depth (m)
*f<sub>f, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
+
*f<sub>f, min</sub> = minimum acceptable infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
 
For practices where flow is delivered directly to the storage reservoir:
 
For practices where flow is delivered directly to the storage reservoir:
 
<math>A_{p}=i\times D\times A_{i}/[d_{i} + (f' \times D)]</math>
 
<math>A_{p}=i\times D\times A_{i}/[d_{i} + (f' \times D)]</math>
Line 127: Line 127:  
* Step 7:  Calculate catchment impervious area to practice permeable (footprint) area ratio, R, also referred to as I/P ratio:
 
* Step 7:  Calculate catchment impervious area to practice permeable (footprint) area ratio, R, also referred to as I/P ratio:
 
<math>R=A_{i}/A_{p}</math><br>
 
<math>R=A_{i}/A_{p}</math><br>
Adjust A<sub>p</sub> or A<sub>i</sub> to keep R between 5 and 20.
+
Adjust *d<sub>p</sub>', d<sub>i</sub>, A<sub>p</sub> or A<sub>i</sub> to keep R between 5 and 20.
    
==Determine the required surface area of the storage reservoir==
 
==Determine the required surface area of the storage reservoir==