Line 27: |
Line 27: |
| |5 to 100 m<sup>2</sup>||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||Yes||None | | |5 to 100 m<sup>2</sup>||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||Yes||None |
| |- | | |- |
− | |'''[[Infiltration trench]] or [[Infiltration chambers]]''' | + | |'''[[Infiltration trenches]] or [[Infiltration chambers]]''' |
| |1 | | |1 |
| |5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 yr | | |5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 yr |
Line 39: |
Line 39: |
| |5:1||Not a constraint||1 to 2||2 to 5||0 to 2||No (infiltrating); Yes (non-infiltrating)||Building Foundation, Trees||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) | | |5:1||Not a constraint||1 to 2||2 to 5||0 to 2||No (infiltrating); Yes (non-infiltrating)||Building Foundation, Trees||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) |
| |- | | |- |
− | |'''[[Vegetated filter strip]]''' | + | |'''[[Vegetated filter strips]]''' |
| |Not applicable | | |Not applicable |
| |5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||Yes||None | | |5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||Yes||None |
Line 47: |
Line 47: |
| |1:1 to 1.2:1||Underdrain recommended <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No (infiltrating); Yes (non-infiltrating)||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) | | |1:1 to 1.2:1||Underdrain recommended <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No (infiltrating); Yes (non-infiltrating)||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) |
| |- | | |- |
− | |'''[[Enhanced swale]] (has checkdams)''' | + | |'''[[Enhanced swales]] (has checkdams)''' |
| |Not applicable | | |Not applicable |
| |5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||Yes||None | | |5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||Yes||None |
| |- | | |- |
− | |'''[[Dry swale]] (Bioswale)''' | + | |'''[[Dry swales]] (Bioswales)''' |
| |1 | | |1 |
| |5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) | | |5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) |
| |- | | |- |
− | |'''[[Exfiltration trench]]''' | + | |'''[[Exfiltration trenches]]''' |
| |1 | | |1 |
| |5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 Yr | | |5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 Yr |
| |} | | |} |