Safety correction factors for calculating design infiltration rates[1]
Ratio of Mean Measured Infiltration Rates Safety Correction Factor
≤ 1 2.5
1.1 to 4.0 3.5
4.1 to 8.0 4.5
8.1 to 16.0 6.5
16.1 or greater 8.5