Difference between revisions of "Rainwater harvesting: Sizing and modeling"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
(12 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
[[File:Cistern Size.png|thumb|Schematic diagram of the inputs and outputs to a rainwater harvesting cistern]]
 
[[File:Cistern Size.png|thumb|Schematic diagram of the inputs and outputs to a rainwater harvesting cistern]]
 
===Simple===
 
===Simple===
 +
The following approximations 
 
Five percent of the average annual yield can be estimated:
 
Five percent of the average annual yield can be estimated:
$$Y_{0.05} = A \times C_{vol,A}\times R_{a} \times e \times 0.05$$
+
<math>Y_{0.05} = A_{c} \times C_{vol,A}\times R_{a} \times e \times 0.05</math>
where:
+
{{plainlist|Where:
{{plainlist|
+
*''Y<sub>0.05</sub>'' is five percent of the average annual yield (L)
*''Y<sub>0.05</sub>'' &#61;  Five percent of the average annual yield (L)
+
*''A<sub>c</sub>'' is the catchment area (m<sup>2</sup>)
*''A'' &#61;  The catchment area (m<sup>2</sup>)
+
*''C<sub>vol, A</sub>'' is the annual runoff coefficient for the catchment
*''C<sub>vol, A</sub>'' &#61;  The annual runoff coefficient for the catchment
+
*''R<sub>a</sub>'' is the average annual rainfall depth (mm)
*''R<sub>a</sub>'' &#61;  The average annual rainfall depth (mm)
+
*''e'' is the efficiency of the pre-storage filter}}
*''e'' &#61; The efficiency of the pre-storage filter}}
 
 
*Filter efficiency (''e'') can be reasonably estimated as 0.9 pending manufacturer’s information.<br>
 
*Filter efficiency (''e'') can be reasonably estimated as 0.9 pending manufacturer’s information.<br>
 
*In a study of three sites in Ontario, STEP found the annual ''C<sub>vol, A</sub>'' of the rooftops to be around 0.8 [http://www.sustainabletechnologies.ca/wp/home/urban-runoff-green-infrastructure/low-impact-development/rainwater-harvesting/performance-evaluation-of-rainwater-harvesting-systems-toronto-ontario/]. This figure includes losses to evaporation, snow being blown off the roof, and a number of overflow events.
 
*In a study of three sites in Ontario, STEP found the annual ''C<sub>vol, A</sub>'' of the rooftops to be around 0.8 [http://www.sustainabletechnologies.ca/wp/home/urban-runoff-green-infrastructure/low-impact-development/rainwater-harvesting/performance-evaluation-of-rainwater-harvesting-systems-toronto-ontario/]. This figure includes losses to evaporation, snow being blown off the roof, and a number of overflow events.
 
+
----
 
 
 
Five percent of the average annual demand can be estimated:
 
Five percent of the average annual demand can be estimated:
$$D_{0.05} = P_{d} \times n\times 18.25$$
+
<math>D_{0.05} = P_{d} \times n\times 18.25</math>
Where:
+
{{plainlist|Where:
{{plainlist|
+
*''D<sub>0.05</sub>'' is five percent of the average annual demand (L)
*''D<sub>0.05</sub>'' &#61; Five percent of the average annual demand (L)
+
*''P<sub>d</sub>'' is the daily demand per person (L)
*''P<sub>d</sub>'' &#61; The daily demand per person (L)
+
*''n'' is the number of occupants}}
*''n'' &#61; The number of occupants}}
+
----
 
 
 
 
 
Then the following calculations are based upon two criteria:
 
Then the following calculations are based upon two criteria:
#A design rainfall depth is to be captured entirely by the RWH system.
+
# A design rainfall depth is to be captured entirely by the RWH system.
#The average annual demand (''D'') is greater than the average annual yield (''Y'') from the catchment.  
+
# The average annual demand (''D'') is greater than the average annual yield (''Y'') from the catchment.  
 
 
 
When \(Y_{0.05}/D_{0.05}<0.33\), the storage volume required can be estimated:
 
When \(Y_{0.05}/D_{0.05}<0.33\), the storage volume required can be estimated:
<math>V_{S} = A \times C_{vol,E}\times R_{d} \times e</math>
+
<math>V_{S} = A_{c} \times C_{vol,E}\times R_{d} \times e</math>
Where:
+
{{plainlist|Where:
{{plainlist|
+
*''V<sub>S</sub>'' is the volume of storage required (L)
*''V<sub>S</sub>'' &#61; Storage volume required (L)
+
*''A<sub>c</sub>'' is the catchment area (m<sup>2</sup>)
*''A'' &#61; The catchment area (m<sup>2</sup>)
+
*''C<sub>vol,E</sub>'' is the design storm runoff coefficient for the catchment
*''C<sub>vol,E</sub>'' &#61; The design storm runoff coefficient for the catchment
+
*''R<sub>d</sub>'' is the design storm rainfall depth (mm), and
*''R<sub>d</sub>'' &#61; The design storm rainfall depth (mm), and
+
*''e'' is the efficiency of the pre-storage filter.}}
*''e'' &#61; The efficiency of the pre-storage filter.}}
 
 
 
*Careful catchment selection means that the runoff coefficient, for a rainstorm event (''C<sub>vol, E</sub>'') should be 0.9 or greater.
 
       
 
  
 +
*Careful catchment selection means that the runoff coefficient, for an individual rainstorm event (''C<sub>vol, E</sub>'') should be 0.9 or greater.
 +
----       
 
Finally, when \(0.33<Y_{0.05}/D_{0.05}<0.7\), the total storage required can be estimated by adding ''Y<sub>0.05</sub>'':
 
Finally, when \(0.33<Y_{0.05}/D_{0.05}<0.7\), the total storage required can be estimated by adding ''Y<sub>0.05</sub>'':
 
<math>TotalStorage = V_{S} + Y_{0.05}</math>
 
<math>TotalStorage = V_{S} + Y_{0.05}</math>
 
+
----
 
==STEP Rainwater Harvesting Tool==
 
==STEP Rainwater Harvesting Tool==
 
[[File:RWH_tank_capacity_table.jpg|thumb|500 px|Quick reference table generated using STEP RWH tool, (data for the City of Toronto (median annual rainfall 678 mm). Optimal cistern size is that providing at least a 2.5% improvement in water savings following an increase of 1,000 Litres in storage capacity.]]
 
[[File:RWH_tank_capacity_table.jpg|thumb|500 px|Quick reference table generated using STEP RWH tool, (data for the City of Toronto (median annual rainfall 678 mm). Optimal cistern size is that providing at least a 2.5% improvement in water savings following an increase of 1,000 Litres in storage capacity.]]
Line 50: Line 44:
  
 
==STEP Treatment Train Tool==
 
==STEP Treatment Train Tool==
{{Clickable button|[[File:TTT.png|400 px|link=http://www.sustainabletechnologies.ca/wp/low-impact-development-treatment-train-tool/]]}}<br>
+
{{Clickable button|[[File:TTT.png|300 px|link=http://www.sustainabletechnologies.ca/wp/low-impact-development-treatment-train-tool/]]}}<br>
 
'''[[Rainwater harvesting: TTT]]'''
 
'''[[Rainwater harvesting: TTT]]'''
 +
 +
==Cistern dimensions==
 +
[[File:Cistern dimensions.jpg|thumb|The blue area indicates the only usable volume in this rainwater harvesting cistern, the depth between the pump inlet and the overflow.]]
 +
The connections into and out of a rainwater cistern can have a dramatic effect on the actual usable volume. The only usable water within the cistern is that above the height of the pump intake, and below the invert of the overflow outlet. This dimension can easily become constrained where the outlet must lie beneath the frost line and where a high powered pump is required to elevate the water many storeys.
 +
* The depth of storage between the elevation of the inlet and overflow is unusable space, so the overflow should be located towards the top of the cistern.
 +
* The depth of storage beneath the pump inlet is unusable, but may also be a useful zone for sediment to settle. A custom or cast-in-place vault could minimise this unused volume by tapering towards the the base. 
 +
[[category:modeling]]

Revision as of 20:52, 20 February 2018

Schematic diagram of the inputs and outputs to a rainwater harvesting cistern

Simple[edit]

The following approximations Five percent of the average annual yield can be estimated:

Where:

  • Y0.05 is five percent of the average annual yield (L)
  • Ac is the catchment area (m2)
  • Cvol, A is the annual runoff coefficient for the catchment
  • Ra is the average annual rainfall depth (mm)
  • e is the efficiency of the pre-storage filter
  • Filter efficiency (e) can be reasonably estimated as 0.9 pending manufacturer’s information.
  • In a study of three sites in Ontario, STEP found the annual Cvol, A of the rooftops to be around 0.8 [1]. This figure includes losses to evaporation, snow being blown off the roof, and a number of overflow events.

Five percent of the average annual demand can be estimated:

Where:

  • D0.05 is five percent of the average annual demand (L)
  • Pd is the daily demand per person (L)
  • n is the number of occupants

Then the following calculations are based upon two criteria:

  1. A design rainfall depth is to be captured entirely by the RWH system.
  2. The average annual demand (D) is greater than the average annual yield (Y) from the catchment.

When \(Y_{0.05}/D_{0.05}<0.33\), the storage volume required can be estimated:

Where:

  • VS is the volume of storage required (L)
  • Ac is the catchment area (m2)
  • Cvol,E is the design storm runoff coefficient for the catchment
  • Rd is the design storm rainfall depth (mm), and
  • e is the efficiency of the pre-storage filter.
  • Careful catchment selection means that the runoff coefficient, for an individual rainstorm event (Cvol, E) should be 0.9 or greater.

Finally, when \(0.33<Y_{0.05}/D_{0.05}<0.7\), the total storage required can be estimated by adding Y0.05:


STEP Rainwater Harvesting Tool[edit]

Quick reference table generated using STEP RWH tool, (data for the City of Toronto (median annual rainfall 678 mm). Optimal cistern size is that providing at least a 2.5% improvement in water savings following an increase of 1,000 Litres in storage capacity.

The Sustainable Technologies Evaluation Program have produced a rainwater harvesting design and costing tool specific to Ontario. The tool is in a simple to use Excel format and is free to download.
Connect the Drops.PNG

STEP Treatment Train Tool[edit]

TTT.png
Rainwater harvesting: TTT

Cistern dimensions[edit]

The blue area indicates the only usable volume in this rainwater harvesting cistern, the depth between the pump inlet and the overflow.

The connections into and out of a rainwater cistern can have a dramatic effect on the actual usable volume. The only usable water within the cistern is that above the height of the pump intake, and below the invert of the overflow outlet. This dimension can easily become constrained where the outlet must lie beneath the frost line and where a high powered pump is required to elevate the water many storeys.

  • The depth of storage between the elevation of the inlet and overflow is unusable space, so the overflow should be located towards the top of the cistern.
  • The depth of storage beneath the pump inlet is unusable, but may also be a useful zone for sediment to settle. A custom or cast-in-place vault could minimise this unused volume by tapering towards the the base.