Difference between revisions of "Low impact development treatment train tool"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
 
(14 intermediate revisions by 5 users not shown)
Line 1: Line 1:
[[File:LIDTTT.png|thumb|Screenshot of the LID TTT]]
+
[[File:LIDTTT.png|thumb|500px|Screenshot of the LID TTT]]
[[File:TTT_menu.PNG|thumb|x450 px|menu bar of the LID TTT]]
+
[[File:TTT_menu.PNG|thumb|x450 px|Menu bar of the LID TTT]]
 +
{{TOClimit|2}}
 +
 
 +
==Overview==
 
The Low Impact Development Treatment Train Tool (LID TTT) is designed to help developers, consultants, municipalities and landowners understand and implement more sustainable stormwater management planning and design practices in their watersheds.  
 
The Low Impact Development Treatment Train Tool (LID TTT) is designed to help developers, consultants, municipalities and landowners understand and implement more sustainable stormwater management planning and design practices in their watersheds.  
  
The LID TTT focuses on the use of Best Management Practices (BMP)’s and Low Impact Development (LID) techniques, and:
+
The LID TTT focuses on the use of Low Impact Development best management practices (BMPs) to meet stormwater management criteria for the site and can be used to:
*analyzes annual and event based runoff volumes,
+
*analyze annual and event based runoff volumes,
 
**including water budget information: surface [[evapotranspiration]], surface runoff, and [[infiltration]] to soil
 
**including water budget information: surface [[evapotranspiration]], surface runoff, and [[infiltration]] to soil
*provides estimates of [[water quality]] improvements.  
+
*provide estimates of [[water quality]] improvements.  
  
The LID TTT is built upon the open source EPA SWMM5 model providing a user-friendly interface for novice modelers and cross-compatibility with SWMM5 for further model development.
+
The LID TTT is built upon the open source EPA SWMM5 hydrologic model providing a user-friendly interface for novice modelers and cross-compatibility with SWMM5 for further model development.
  
 
The LID TTT has been developed in partnership between [http://www.lsrca.on.ca/ Lake Simcoe Region Conservation Authority], [https://www.creditvalleyca.ca/ Credit Valley Conservation], and [https://trca.ca/ Toronto and Region Conservation Authority].
 
The LID TTT has been developed in partnership between [http://www.lsrca.on.ca/ Lake Simcoe Region Conservation Authority], [https://www.creditvalleyca.ca/ Credit Valley Conservation], and [https://trca.ca/ Toronto and Region Conservation Authority].
Line 16: Line 19:
 
*[[Filter strips: TTT|Vegetated filter strips]]
 
*[[Filter strips: TTT|Vegetated filter strips]]
 
*[[Infiltration: TTT|Infiltration trenches]]
 
*[[Infiltration: TTT|Infiltration trenches]]
*[[Permeable paving: TTT| Permeable paving]]
+
*[[Permeable pavements: TTT| Permeable pavements]]
 
*[[Rainwater harvesting: TTT|Rainwater harvesting]]
 
*[[Rainwater harvesting: TTT|Rainwater harvesting]]
 
*[[Swales: TTT|Swales]]
 
*[[Swales: TTT|Swales]]
 
*[[Dry ponds: TTT|Dry ponds]]
 
*[[Dry ponds: TTT|Dry ponds]]
*[[Pretreatment: TTT|OGS and filters]]
 
  
 
This links to the project page, where you can download your free copy of the LID TTT.
 
This links to the project page, where you can download your free copy of the LID TTT.
  
{{Clickable button|[[File:TTT.png|350 px|link=http://www.sustainabletechnologies.ca/wp/low-impact-development-treatment-train-tool/]]}}
+
{{Clickable button|[[File:TTT.png|350 px|link=https://sustainabletechnologies.ca/lid-ttt/]]}}
 +
 
 +
==How to download & install the Tool==
 +
View the Step-by-step instructional video below on how to download and install the LID TTT. This video covers how to set up your model, add LIDs and analyze results for pre- to post-development scenario<br>
 +
<br>
 +
{{#widget:YouTube|float left|id=pLdcT-6Qq4M}}
 +
 
 +
==How to use the Tool==
 +
View the Step-by-step instructional video below on how to use the LID TTT for you LID BMP projects.<br>
 +
<br>
 +
{{#widget:YouTube|float left|id=aKG5FuEbp2g}}
 +
 
 +
[[Category: Modeling]]
 +
 
 +
==How to size your LID using an I:P ratio==
 +
View the Step-by-step instructional video below on how to use the LID TTT to route a simple residential sub-catchment to a [[bioswale]] feature, and shows users to consider the Impervious to pervious (or I:P) ratio in sizing the LID.<br>
 +
<br>
 +
{{#widget:YouTube|float left|id=fLfqnOUU4Zg}}
  
 
[[Category: Modeling]]
 
[[Category: Modeling]]

Latest revision as of 16:04, 1 June 2023

Screenshot of the LID TTT
Menu bar of the LID TTT

Overview[edit]

The Low Impact Development Treatment Train Tool (LID TTT) is designed to help developers, consultants, municipalities and landowners understand and implement more sustainable stormwater management planning and design practices in their watersheds.

The LID TTT focuses on the use of Low Impact Development best management practices (BMPs) to meet stormwater management criteria for the site and can be used to:

The LID TTT is built upon the open source EPA SWMM5 hydrologic model providing a user-friendly interface for novice modelers and cross-compatibility with SWMM5 for further model development.

The LID TTT has been developed in partnership between Lake Simcoe Region Conservation Authority, Credit Valley Conservation, and Toronto and Region Conservation Authority.

Integration with this guide is through suggested 'starting point' values for design parameters for the following BMP types:

This links to the project page, where you can download your free copy of the LID TTT.

TTT.png

How to download & install the Tool[edit]

View the Step-by-step instructional video below on how to download and install the LID TTT. This video covers how to set up your model, add LIDs and analyze results for pre- to post-development scenario

How to use the Tool[edit]

View the Step-by-step instructional video below on how to use the LID TTT for you LID BMP projects.

How to size your LID using an I:P ratio[edit]

View the Step-by-step instructional video below on how to use the LID TTT to route a simple residential sub-catchment to a bioswale feature, and shows users to consider the Impervious to pervious (or I:P) ratio in sizing the LID.