Liner

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

An impermeable liner is incorporated into non-infiltrating practices such as stormwater planters, and may be applied in permeable pavements installations where separation from the native soils and groundwater is required.

  • Waterproof containment can be created using concrete or a plastic membrane/liner (HDPE or EPDM are common materials).
    • When the membrane is being used directly in the ground, punctures from stones can be prevented by compacting a layer sand (30 - 50 mm) over the soil prior to installing the membrane.
    • Alternatively, a manufactured cushion fabric (geotextile) can be employed for this purpose.
    • The top surface of the membrane must also be protected from stone and gravel being used for inside the BMP. Again, sand or a cushion fabric may be used.