Difference between revisions of "Inlets"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
(Created page with "{{{| class="wikitable" |- !Trench drains !Curb cuts !Inlet sumps !Depressed drains |- | *A long, covered channel that collects directs water into the BMP. *An excellent s...")
 
(22 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{{| class="wikitable"
+
Concentrated flow inlets are associated with LID practices such as [[Bioretention]], [[Stormwater planters]], [[Infiltration trenches]] and [[infiltration chambers|chambers]].
 +
Sheet flow alternatives include [[level spreaders]], [[gravel diaphragms]] and [[vegetated filter strips]].
 +
Practices such as [[permeable paving]] and [[green roofs]] receive precipitation directly, whilst [[exfiltration trenches]] are connected directly to conventional storm sewers. 
 +
 
 +
Inlets for BMPs in the right of way should be located:
 +
*At all sag points in the gutter grade
 +
*Immediately upgrade of median breaks, crosswalks, and street intersections. 
 +
 
 +
It is good practice to have several inlets sized to split higher flow between a number of smaller BMPs or along the length of a linear pratice ([[Overflow|Offline overflow]]).
 +
 
 +
{| class="wikitable"
 
|-
 
|-
!Trench drains
+
!style="width: 25%"|Trench drains
![[Curb cuts]]
+
!style="width: 25%"|[[Curb cuts]]
!Inlet sumps
+
!style="width: 25%"|Inlet sumps
!Depressed drains
+
!style="width: 25%"|Depressed drains
 
|-
 
|-
 
|
 
|
Line 12: Line 22:
 
*Drains may be configured either perpendicular or parallel to the flow direction of the roadway, collecting runoff and directing to a single inlet in the BMP.
 
*Drains may be configured either perpendicular or parallel to the flow direction of the roadway, collecting runoff and directing to a single inlet in the BMP.
 
|
 
|
*Inlet aprons or depressions increase inflow effectiveness. Aprons typically drop 50 mm into the bioretention cell, with another 50 mm drop behind the curb to maintain inflow as debris collects.
+
*Inlet aprons or depressions increase inflow effectiveness of curb cuts.  
*Gutters with steep cross slopes can be hazardous, especially to people bicycling. Curbside and protected bike lanes along concrete aprons should be at least 1.8 m to give cyclists adequate clear width from the curb and any pavement seams. Aprons could also be marked visually to indicate their perimeter.  
+
*Steeply angled aprons can be hazardous, especially to people bicycling. Curbside and protected bike lanes along concrete aprons should be at least 1.8 m to give cyclists adequate clear width from the curb and any pavement seams. Aprons can also be marked visually to indicate their perimeter.  
*Where the curb alignment along the street is straight, the curb opening may optionally have a bar across the top of the inlet. For aprons into bioretention swales, the curb may angle into the cell to improve conveyance of gutter flow into the facility in the planting strip.
+
*For aprons into [[bioretention]], the curb may angle into the cell to improve conveyance of gutter flow into the facility. Aprons typically drop 50 mm into the bioretention cell, with another 50 mm drop behind the curb to maintain inflow as debris collects.
 
*A depressed concrete apron can be cast in place or retrofitted in by grinding down the existing concrete pavement.
 
*A depressed concrete apron can be cast in place or retrofitted in by grinding down the existing concrete pavement.
 +
*Where the curb alignment along the street is straight, the curb opening may optionally have a bar across the top of the inlet.
 
|
 
|
 
*An inlet sump is recommended to settle and separate sediment from runoff where a large amount of debris is expected.
 
*An inlet sump is recommended to settle and separate sediment from runoff where a large amount of debris is expected.
*Water drains into a catch basin, where debris settles in its sump. After [[pretreatement]], water drains via a pipe or opening into the BMP.
+
*Water drains into a catch basin, where debris settles in its sump. After [[pretreatment]], water drains via a pipe or opening into the BMP.
*The sump can be directly connected to a perforated [[underdrain]] pipe to distribute the flow to the [[bioretention]] or connected [[extended tree pits|tree pits]].
+
*The sump can be directly connected to a perforated [[underdrain]] pipe to distribute the flow to the [[bioretention]], supported [[soil cells]] or underground practices such a [[trenches]] or [[chambers]] .
 
*Sump inlets should not be sited where pedestrians will have to negotiate with them.
 
*Sump inlets should not be sited where pedestrians will have to negotiate with them.
 
|
 
|
Line 25: Line 36:
 
*Depressed drains are a potential solution for bioretention cells on sloped streets where directing runoff into the cell is a challenge.
 
*Depressed drains are a potential solution for bioretention cells on sloped streets where directing runoff into the cell is a challenge.
 
*This style of inlet can be combined with a curb cut, to maintain capacity in case debris clogs the grate.
 
*This style of inlet can be combined with a curb cut, to maintain capacity in case debris clogs the grate.
 +
|-
 +
|style="vertical-align: top;"|{{:Trench drains: Gallery}}
 +
|style="vertical-align: top;"|{{:Curb cuts: Gallery}}
 +
|style="vertical-align: top;"|{{:Inlet sumps: Gallery}}
 +
|style="vertical-align: top;"|{{:Depressed drains: Gallery}}
 
|}
 
|}
  
 
==External links==
 
==External links==
 
https://nacto.org/publication/urban-street-stormwater-guide/stormwater-elements/bioretention-design-considerations/inlet-design/
 
https://nacto.org/publication/urban-street-stormwater-guide/stormwater-elements/bioretention-design-considerations/inlet-design/

Revision as of 19:34, 25 October 2018

Concentrated flow inlets are associated with LID practices such as Bioretention, Stormwater planters, Infiltration trenches and chambers. Sheet flow alternatives include level spreaders, gravel diaphragms and vegetated filter strips. Practices such as permeable paving and green roofs receive precipitation directly, whilst exfiltration trenches are connected directly to conventional storm sewers.

Inlets for BMPs in the right of way should be located:

  • At all sag points in the gutter grade
  • Immediately upgrade of median breaks, crosswalks, and street intersections.

It is good practice to have several inlets sized to split higher flow between a number of smaller BMPs or along the length of a linear pratice (Offline overflow).

Trench drains Curb cuts Inlet sumps Depressed drains
  • A long, covered channel that collects directs water into the BMP.
  • An excellent solution for streets where walking across the entire surface is to be encouraged. They can be designed as detectable edges or part of a detectable edge, and may be used to help define curbless or 'complete streets'.
  • Trenches may either be shallow (where runoff volume is less of an issue) or deep and covered by a metal grate. Deeper trench drains may gather sediment and require frequent maintenance.
  • Drains may be configured either perpendicular or parallel to the flow direction of the roadway, collecting runoff and directing to a single inlet in the BMP.
  • Inlet aprons or depressions increase inflow effectiveness of curb cuts.
  • Steeply angled aprons can be hazardous, especially to people bicycling. Curbside and protected bike lanes along concrete aprons should be at least 1.8 m to give cyclists adequate clear width from the curb and any pavement seams. Aprons can also be marked visually to indicate their perimeter.
  • For aprons into bioretention, the curb may angle into the cell to improve conveyance of gutter flow into the facility. Aprons typically drop 50 mm into the bioretention cell, with another 50 mm drop behind the curb to maintain inflow as debris collects.
  • A depressed concrete apron can be cast in place or retrofitted in by grinding down the existing concrete pavement.
  • Where the curb alignment along the street is straight, the curb opening may optionally have a bar across the top of the inlet.
  • An inlet sump is recommended to settle and separate sediment from runoff where a large amount of debris is expected.
  • Water drains into a catch basin, where debris settles in its sump. After pretreatment, water drains via a pipe or opening into the BMP.
  • The sump can be directly connected to a perforated underdrain pipe to distribute the flow to the bioretention, supported soil cells or underground practices such a trenches or chambers .
  • Sump inlets should not be sited where pedestrians will have to negotiate with them.
  • Runoff in the gutter drops into a grate-covered drain before flowing into the BMP. Drain covers must be compatible with bicycling and walking; grid covers are preferred.
  • Depressed drains are a potential solution for bioretention cells on sloped streets where directing runoff into the cell is a challenge.
  • This style of inlet can be combined with a curb cut, to maintain capacity in case debris clogs the grate.
Depressed drains: Gallery

External links[edit]

https://nacto.org/publication/urban-street-stormwater-guide/stormwater-elements/bioretention-design-considerations/inlet-design/

  1. Mullen, T.J. Prioritizing trash capture and clean oceans: Stormwater hoods and traps lead the way in effectiveness. The Municipal magazine. June 1, 2022. Accessed: https://www.themunicipal.com/2022/06/prioritizing-trash-capture-and-clean-oceans-stormwater-hoods-and-traps-lead-the-way-in-effectiveness/
  2. Erickson, A.J. and Hernick, M.A., 2019. Capture of Gross Solids and Sediment by Pretreatment Practices for Bioretention. Accessed: https://conservancy.umn.edu/handle/11299/201607
  3. Halvorson, Tighe & Bond Studio. n.d. Halvorson, Tighe & Bond Studio. Retrieved from: https://www.halvorsondesign.com/willard-street-drainage
  4. Philadelphia Water Department. n.d. Chapter 4 Stormwater Management Practice Guidance 4.1 Bioinfiltration/Bioretention. Retrieved from: https://water.phila.gov/development/stormwater-plan-review/manual/chapter-4/4-1-bioinfiltration-bioretention/
  5. National Association of City Transportation Officials (NACTO). 2017. Urban Street Stormwater Guide - Inlet Design. Retrieved from: https://nacto.org/publication/urban-street-stormwater-guide/stormwater-elements/bioretention-design-considerations/inlet-design/
  6. Philadelphia Water Department. 2020. Stormwater Management Guidance Manual: Version 3.2. Accessed from: https://www.pwdplanreview.org/upload/manual_pdfs/PWD-SMGM-v3.2-20201001.pdf