Difference between revisions of "Infiltration chambers"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
Line 38: Line 38:
  
 
==Planning Considerations==
 
==Planning Considerations==
All types of modular systems require a bedding of angular clear stone to permit infiltration, and provide a foundation for the installation:  
+
All types of modular infiltration systems require a bedding of angular clear stone to permit infiltration, and provide a foundation for the installation:  
 
*Plastic chambers usually have a parabolic shape to support the load above. The spaces between rows of plastic pipes or chambers are filled with clear stone to support overlying structures.
 
*Plastic chambers usually have a parabolic shape to support the load above. The spaces between rows of plastic pipes or chambers are filled with clear stone to support overlying structures.
 
*Concrete vaults are often rectangular-shaped and can, in some circumstances, be employed without any additional cover. However, a minimum of 20 cm cover is recommended for most applications. Where this cover is planting soil this can support turf grass. Greater planting soil depths are required to support more deeply rooting plants like perennials and shrubs (45 to 60 cm) and trees (85 to 100 cm).
 
*Concrete vaults are often rectangular-shaped and can, in some circumstances, be employed without any additional cover. However, a minimum of 20 cm cover is recommended for most applications. Where this cover is planting soil this can support turf grass. Greater planting soil depths are required to support more deeply rooting plants like perennials and shrubs (45 to 60 cm) and trees (85 to 100 cm).

Revision as of 18:26, 27 July 2020

Overview[edit]

As their name suggests infiltration chambers work exclusively to infiltrate stormwater. They are an underground facility and are often used beneath parking lots or playing fields to treat flow routed from other areas.

Infiltration chambers are an ideal technology for:

  • Installing below any type of surface or landscape
  • Receiving and infiltrating large volumes of water

The fundamental components of an infiltration chamber system are:

  • Pretreatment devices to retain trash, debris, sediment and floatables and prevent clogging of inlets, underlying native soil and outlets;
  • Storage reservoir consisting of structurally reinforced chambers, vaults, crates, perforated pipes or other void-forming structures embedded in coarse aggregate;
  • Pipes and possibly flow control structures to convey water into and out of the practice; and
  • Geotextiles to maintain separation between the storage reservoir and surrounding native soil.
System type Perforated pipes Vaults Arched chambers Crates
SWM Pipe.jpg SWM Vaults.jpg SWM Arches.jpg SWM Crates.jpg
Materials Plastic or Metal Concrete Plastic Plastic
Footprint Medium Small Medium Small
Stackable Yes No Yes Yes
Porosity 60-65% 75-85% 50-65% 95%
Maintenance access Moderate Excellent Moderate Difficult
Standard strength H-20 H-25 H-20 H-20 to H-25

Planning Considerations[edit]

All types of modular infiltration systems require a bedding of angular clear stone to permit infiltration, and provide a foundation for the installation:

  • Plastic chambers usually have a parabolic shape to support the load above. The spaces between rows of plastic pipes or chambers are filled with clear stone to support overlying structures.
  • Concrete vaults are often rectangular-shaped and can, in some circumstances, be employed without any additional cover. However, a minimum of 20 cm cover is recommended for most applications. Where this cover is planting soil this can support turf grass. Greater planting soil depths are required to support more deeply rooting plants like perennials and shrubs (45 to 60 cm) and trees (85 to 100 cm).

Design[edit]

Sizing[edit]

Infiltration: Sizing and modeling

Modeling[edit]

Materials[edit]

Chambers[edit]

Plastic chambers[edit]

Chambers should be compliant with:

  • CSA B184-17 "Polymeric subsurface stormwater management structures".
  • ASTM F2418-16a “Standard Specification for Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers”.

Allowable loads for the chambers must be determined in accordance with ASTM F2787-13 “Standard Practice for Structural Design of Thermoplastic Corrugated Wall Stormwater Collection Chambers”.

Concrete vaults[edit]

Concrete vault-type systems should be compliant with:

Aggregates[edit]

Note the uniform size and angularity of this clear stone sample. Note also that the fragments all appear to have a film of fine particles adhering; this material would be improved by being washed prior to use.

This article gives recommendations for aggregate to be used to store water for infiltration. This is usually called 'clear stone' at aggregate yards.

To see an analysis of Ontario Standard Specifications for granular materials, see OPSS aggregates.

For advice on decorative surface aggregates see Stone


Gravel used for underdrains in bioretention, infiltration trenches and chambers, and exfiltration trenches should be 20 or 50 mm, uniformly-graded, clean (maximum wash loss of 0.5%), crushed angular stone that has a porosity of 0.4[1].

The clean wash to prevent rapid accumulation of fines from the aggregate particles in the base of the reservoir. The uniform grading and the angularity are important to maintain pore throats and clear voids between particles. (i.e. achieve the porosity). Porosity and permeability are directly influenced by the size, gradation and angularity of the particles [2]. See jar test for on-site verification testing protocols.

Gravel with structural requirements should also meet the following criteria:

  • Minimum durability index of 35
  • Maximum abrasion of 10% for 100 revolutions and maximum of 50% for 500 revolutions

Standard specifications for the gradation of aggregates are maintained by ASTM D2940


Other[edit]

Construction[edit]

Construction

Gallery[edit]

External links[edit]

In our effort to make this guide as functional as possible, we have decided to include proprietary systems and links to manufacturers websites.
Inclusion of such links does not constitute endorsement by the Sustainable Technologies Evaluation Program.
Lists are ordered alphabetically; link updates are welcomed using the form below.

Plastic chambers[edit]

Concrete chambers[edit]


  1. Porosity of Structural Backfill, Tech Sheet #1, Stormtech, Nov 2012, http://www.stormtech.com/download_files/pdf/techsheet1.pdf accessed 16 October 2017
  2. 2.0 2.1 2.2 Judge, Aaron, "Measurement of the Hydraulic Conductivity of Gravels Using a Laboratory Permeameter and Silty Sands Using Field Testing with Observation Wells" (2013). Dissertations. 746. http://scholarworks.umass.edu/open_access_dissertations/746