Changes

Jump to navigation Jump to search
m
no edit summary
Line 1: Line 1:  +
The [[green roofs|green roof]] media used in Ontario can be classed according to proportion of composted biological material. Some existing installations use materials which comply with FLL guidelines, whilst others use a much higher proportion of [[compost]]<ref>Hill, J., Drake, J., and Sleep, B. (2016). “Comparisons of extensive green roof media in Southern Ontario.” Ecological Engineering, Elsevier B.V., 94, 418–426.</ref>.
 +
 
ASTM International have a number of standards relating to various design considerations for green roofs. These standards provide good technical advice on the testing of systems and components.
 
ASTM International have a number of standards relating to various design considerations for green roofs. These standards provide good technical advice on the testing of systems and components.
 
Of particular note are:
 
Of particular note are:
*E2399 Standard Test Method for Maximum Media Density for Dead Load Analysis of Vegetative (Green) Roof Systems[https://www.astm.org/Standards/E2399.htm], and
+
*Standard Test Method for Maximum Media Density for Dead Load Analysis of Vegetative (Green) Roof Systems[https://www.astm.org/Standards/E2399.htm E2399], and
*E2396 Test Method for Saturated Water Permeability of Granular Drainage Media [https://www.astm.org/Standards/E2396.htms].
+
*Test Method for Saturated Water Permeability of Granular Drainage Media [https://www.astm.org/Standards/E2396.htms E2396].
    
When these tests are completed, the results should be interpreted in relation to the objectives of the green roof. A product complying with overseas guidelines may not serve the needs of a green roof installed in Ontario. In particular, the [http://www.fll.de/shop/english-publications/green-roofing-guideline-2008-file-download.html FLL guide] recommends green roof media specifications which may not provide optimal stormwater management or vegetation in our region.  
 
When these tests are completed, the results should be interpreted in relation to the objectives of the green roof. A product complying with overseas guidelines may not serve the needs of a green roof installed in Ontario. In particular, the [http://www.fll.de/shop/english-publications/green-roofing-guideline-2008-file-download.html FLL guide] recommends green roof media specifications which may not provide optimal stormwater management or vegetation in our region.  
The green roof media used in Ontario can be classed according to proportion of composted biological material. Some existing installations  use materials which comply with FLL guidelines, whilst others use a much higher proportion of [[compost]].[http://grit.daniels.utoronto.ca/wp-content/uploads/2016/06/Comparisons-of-extensive-green-roof-media-in-Southern-Ontario.pdf]
  −
   
In many proprietary systems the default option for planting medium will be a granular material with very low organic matter content. However, many companies can arrange for a high [[organic matter]] alternative to be substituted if requested.   
 
In many proprietary systems the default option for planting medium will be a granular material with very low organic matter content. However, many companies can arrange for a high [[organic matter]] alternative to be substituted if requested.   
    
{|class="wikitable"
 
{|class="wikitable"
|+ Considerations for using a 'high organic' planting medium
+
|+ Considerations for using a 'high organic', [[compost]] based planting medium
 
|-  
 
|-  
 
!Benefits
 
!Benefits
Line 17: Line 17:  
|
 
|
 
*Increased water holding capacity, which benefits both vegetation health and stormwater retention  
 
*Increased water holding capacity, which benefits both vegetation health and stormwater retention  
*Often lighter weight, even when saturated
+
*Lighter weight, even when saturated
 
|
 
|
 
*Increased [[phosphorus]] concentration in runoff water, however this may be mitigated by the reduced runoff volume resulting in a lower loading overall  
 
*Increased [[phosphorus]] concentration in runoff water, however this may be mitigated by the reduced runoff volume resulting in a lower loading overall  
Line 23: Line 23:  
|}
 
|}
   −
Increasing the depth of planting medium from 10 cm to 15 cm has been shown to benefit the vegetation <ref>MacIvor JS, Margolis L, Puncher CL, Carver Matthews BJ. Decoupling factors affecting plant diversity and cover on extensive green roofs. J Environ Manage. 2013;130:297-305. doi:10.1016/j.jenvman.2013.09.014.</ref>; stormwater retention was not improved with this increase in depth <ref name =Hill/>
+
Increasing the depth of planting medium from 10 cm to 15 cm has been shown to benefit the vegetation <ref>MacIvor JS, Margolis L, Puncher CL, Carver Matthews BJ. Decoupling factors affecting plant diversity and cover on extensive green roofs. J Environ Manage. 2013;130:297-305. doi:10.1016/j.jenvman.2013.09.014.</ref>; stormwater retention was not improved with this increase in depth <ref>Hill, J., Drake, A. P. J., Sleep, B., and Margolis, L. (2017). “Influences of Four Extensive Green Roof Design Variables on Stormwater Hydrology.” Journal of Hydrologic Engineering.</ref>
 
+
----
 
[[category:materials]]
 
[[category:materials]]
[[category:infiltration]]
   
[[category:green infrastructure]]
 
[[category:green infrastructure]]
8,255

edits

Navigation menu