Difference between revisions of "Flow through an orifice"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
m
m
Line 4: Line 4:
  
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*''B'' is the clogging factor (between 0.5 (for matured installation) and 1 (for a new perfectly performing BMP)),     
+
*''B'' is the clogging factor (between 0.5 (for matured installation) and 1 (for a new perfectly performing orifice)),     
 
*''C<sub>d</sub>'' is the coefficient of discharge (usually 0.61 for a plate, or 0.8 for a pipe),  
 
*''C<sub>d</sub>'' is the coefficient of discharge (usually 0.61 for a plate, or 0.8 for a pipe),  
 
*''A<sub>o</sub>'' is the area of the orifice (m<sup>2</sup>),  
 
*''A<sub>o</sub>'' is the area of the orifice (m<sup>2</sup>),  

Revision as of 19:49, 17 March 2019

Orifices are simply holes which restrict the flow of water. They may be used at the bottom end of an LID practice to add some flow control.

Where:

  • B is the clogging factor (between 0.5 (for matured installation) and 1 (for a new perfectly performing orifice)),
  • Cd is the coefficient of discharge (usually 0.61 for a plate, or 0.8 for a pipe),
  • Ao is the area of the orifice (m2),
  • g is acceleration due to gravity = 9.81 m/s2, and
  • h is the head of water over the centre of the orifice (m).

See also[edit]