Difference between revisions of "Filter strips: TTT"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
m
m
 
(One intermediate revision by the same user not shown)
Line 15: Line 15:
 
|Thickness (mm)||If topsoil has been amended [[Absorbent landscapes]]
 
|Thickness (mm)||If topsoil has been amended [[Absorbent landscapes]]
 
|-
 
|-
|Porosity (fraction)||Suggest range 0.35 – 0.4, unless otherwise tested
+
|Porosity (fraction)||Suggest around 0.4, unless otherwise tested.
 
|-
 
|-
 
|Field capacity (fraction)||Rowspan=5|Will vary according to native or amended topsoil<ref> Oregon State Univ., Corvallis. Dept. of Civil, Construction and Environmental Engineering.; Environmental Protection Agency, Cincinnati ONRMRL. Storm Water Management Model Reference Manual Volume I Hydrology (Revised). 2016:233. https://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=P100NYRA.txt Accessed August 23, 2017.</ref>
 
|Field capacity (fraction)||Rowspan=5|Will vary according to native or amended topsoil<ref> Oregon State Univ., Corvallis. Dept. of Civil, Construction and Environmental Engineering.; Environmental Protection Agency, Cincinnati ONRMRL. Storm Water Management Model Reference Manual Volume I Hydrology (Revised). 2016:233. https://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=P100NYRA.txt Accessed August 23, 2017.</ref>
Line 29: Line 29:
 
|Design drawdown time (hrs)||Will be determined by regulatory authority, often 48 - 72 hours to reduce nuisance from [[Wildlife#Mosquitoes|mosquitoes]]
 
|Design drawdown time (hrs)||Will be determined by regulatory authority, often 48 - 72 hours to reduce nuisance from [[Wildlife#Mosquitoes|mosquitoes]]
 
|}
 
|}
[[category:modelling]]
+
[[category:modeling]]

Latest revision as of 22:24, 20 November 2018

TTT.png

Vegetated filter strips are found within the LID toolbox
Surface
Berm height (mm) This is the height of the curb which constrains the overland sheet flow of water. Where the bottom of the slope discharges directly into another LID facility without impedance, the value is 0.
Surface roughness (Manning’s n) Lower numbers indicate less surface obstruction and result in faster flow. See Turf for ideas of a good number according to mowing practices.
Surface slope (%) If the slope > 3%, consider using level spreaders to reduce erosion of the surface under high flow velocities.
Soil (native underlying soil, or amended topsoil)
Thickness (mm) If topsoil has been amended Absorbent landscapes
Porosity (fraction) Suggest around 0.4, unless otherwise tested.
Field capacity (fraction) Will vary according to native or amended topsoil[1]
Wilting point (fraction)
Conductivity (mm/hr)
Conductivity slope
Suction head (mm)
Design drawdown time (hrs) Will be determined by regulatory authority, often 48 - 72 hours to reduce nuisance from mosquitoes
  1. Oregon State Univ., Corvallis. Dept. of Civil, Construction and Environmental Engineering.; Environmental Protection Agency, Cincinnati ONRMRL. Storm Water Management Model Reference Manual Volume I Hydrology (Revised). 2016:233. https://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=P100NYRA.txt Accessed August 23, 2017.