Difference between revisions of "Bioretention: Sizing"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
(26 intermediate revisions by the same user not shown)
Line 21: Line 21:
 
|  
 
|  
 
* 0.7 for wood based
 
* 0.7 for wood based
* 0.4 for aggregate
+
* 0.4 for [[stone]]
 
|-
 
|-
 
| [[Bioretention: Filter media|filter media]] (''d<sub>m</sub>'')
 
| [[Bioretention: Filter media|filter media]] (''d<sub>m</sub>'')
Line 28: Line 28:
 
* 600 mm to support flowering [[perennials]] and decorative [[grasses]]
 
* 600 mm to support flowering [[perennials]] and decorative [[grasses]]
 
* 1000 mm to support [[trees]]
 
* 1000 mm to support [[trees]]
| 0.3
+
|
 +
*[[Bioretention media storage| 0.4]] for sandy mix
 +
* 0.35 for a more loamy mix.
 
|-
 
|-
 
| [[choker layer|Choker course]]
 
| [[choker layer|Choker course]]
Line 48: Line 50:
 
==Calculate the maximum overall depth==
 
==Calculate the maximum overall depth==
 
*Step 1: Determine what the planting needs are and assign appropriate depth of media, using the table above.  
 
*Step 1: Determine what the planting needs are and assign appropriate depth of media, using the table above.  
*Step 2: Select an underdrain pipe diameter (typically 100 - 200 mm), assign this as an 'embedding' depth.   
+
*Step 2: Select an underdrain pipe diameter (typically 100 - 200 mm), assign this as an 'embedding' depth. *Note that this component does not apply if a downstream riser is being used to control an extended saturation zone.   
*Step 3: Calculate the maximum possible storage reservoir depth beneath the pipe (''d<sub>s</sub>''):
+
*Step 3: Calculate the maximum possible storage reservoir depth beneath the pipe (''d<sub>s, max</sub>'', mm):
<math>d_{s}=\frac{f'\times 96}{0.4}</math>
+
<math>d_{s, max}=f'\times t</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*''f''' = Design infiltration rate in mm/hr, and
+
*''f''' = Design infiltration rate (mm/hr), and
*96 is the desired drainage time in hours
+
*''t'' = [[Drainage time]] (hrs). Check local regulations for drainage time requirements.}}
*0.4 is the void ratio of [[reservoir gravel|clear stone]]}}
 
  
 
===Additional step for system without underdrain===
 
===Additional step for system without underdrain===
*Step 4: Determine maximum permissible ponding depth (''d<sub>p</sub>''):
+
* Step 4: Determine maximum permissible ponding depth (''d<sub>p, max</sub>''):
<math>d_{p}=\frac{f'\times48}{0.4}</math>
+
<math>d_{p, max}=f'\times48</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*''f''' = Design infiltration rate in mm/hr, and
+
*''f''' = Design infiltration rate (mm/hr), and
*48 is the desired drainage time of the ponding in hours
+
*48 = Drainage time of the ponding (hrs)
*0.4 is the void ratio of [[reservoir gravel|clear stone]] *Note that conceptually the drainage of the ponded area is limited by ex-filtration at the base of the practice.}}
+
*Note that conceptually the drainage of the ponded area is limited by ex-filtration at the base of the practice.}}
 
* Step 5: Sum total depth of bioretention, and compare to available space above water table and bedrock. Adjust if necessary.
 
* Step 5: Sum total depth of bioretention, and compare to available space above water table and bedrock. Adjust if necessary.
  
 
==Calculate the remaining dimensions==
 
==Calculate the remaining dimensions==
 
* Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
 
* Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
* Step 7: Calculate the required total storage (m<sup>3</sup>):
+
* Step 7: Calculate the required total storage (S<sub>T</sub>, m<sup>3</sup>):
<math>Storage=RVC_T\times A_c\times C\times 0.1</math>
+
<math>S_{T}=RVC_T\times A_c\times 10</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
 
*''RVC<sub>T</sub>'' is the Runoff volume control target (mm),
 
*''RVC<sub>T</sub>'' is the Runoff volume control target (mm),
*''A<sub>c</sub>'' is the catchment area (Ha),
+
*''A<sub>c</sub>'' is the catchment area (Ha), and
*''C'' is the runoff coefficient of the catchment area, and
+
* 10 is the units correction between m<sup>3</sup> and mm.Ha.}}
* 0.1 is the units correction between m<sup>3</sup> and mm.Ha.}}
 
 
* Step 8. Divide required storage (m<sup>3</sup>) by the 1 dimensional storage (in m) to find the required footprint area (''A<sub>p</sub>'') for the bioretention in m<sup>2</sup>.  
 
* Step 8. Divide required storage (m<sup>3</sup>) by the 1 dimensional storage (in m) to find the required footprint area (''A<sub>p</sub>'') for the bioretention in m<sup>2</sup>.  
* Step 9. Calculate the peak flow rate (''Q<sub>p</sub>'', in L/s) through the filter media:
+
* Step 9. Calculate the peak [[flow through perforated pipe|flow rate through the perforated pipe]],  
 +
* Step 10. Calculate the peak [[flow through media|flow rate through the filter media]],
 +
* Step 11. Determine if downstream [[flow control]] is required to achieve hydrologic objectives.
  
 
==Additional calculations==
 
==Additional calculations==
===Drainage time (3D)===
+
 
 +
===Calculating infiltration practice drainage in 1 dimension===
 +
This spreadsheet compares drainage in a single dimension under zero head conditions, mean head conditions and falling head conditions. It provides a more conservative measurement of the drainage time for the purposes of groundwater mounding (where a shorter drainage time causes a greater impact).
 +
 
 +
{{Clickable button|[[Media:Darcy drainage.xlsx|Download drainage time calculator(.xlsx)]]}}
 +
 
 +
===Drainage time (3D)<ref>Woods Ballard, B., S. Wilson, H. Udale-Clarke, S. Illman, T. Scott, R. Ahsley, and R. Kellagher. 2016. The SuDS Manual. 5th ed. CIRIA, London.</ref>===
 
[[file:Hydraulic radius.png|thumb|Two practice areas of 9 m<sup>2</sup>.<br> P = 12 m (left), P = 20 m (right)]]
 
[[file:Hydraulic radius.png|thumb|Two practice areas of 9 m<sup>2</sup>.<br> P = 12 m (left), P = 20 m (right)]]
In some situations, it may be possible to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration.  
+
In some situations, it may be desirable to reduce the size of the bioretention required, by accounting for rapid drainage.  
Note that narrow, linear bioretention features drain faster than round or blocky footprint geometries.  
+
Typically, this is only worth exploring over sandy soils with rapid infiltration.  
 +
 
 +
Note that narrow, linear bioretention features (or [[bioswales]]) drain faster than round or blocky footprint geometries.  
 +
 
 
*Begin the drainage time calculation by dividing the area of the practice (''A<sub>p</sub>'') by the perimeter (''P'').
 
*Begin the drainage time calculation by dividing the area of the practice (''A<sub>p</sub>'') by the perimeter (''P'').
 
*To estimate the time (''t'') to fully drain the facility:  
 
*To estimate the time (''t'') to fully drain the facility:  
:<math>t=\frac{V_{R}A_{p}}{f'P}ln\left [ \frac{\left (d+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
+
:<math>t=\frac{V_{R}A_{p}}{f'P}ln\left [ \frac{\left (d_{T}+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
 
*''V<sub>R</sub>'' is the void ratio of the media,  
 
*''V<sub>R</sub>'' is the void ratio of the media,  
Line 90: Line 101:
 
*''f''' is the design infiltration rate (mm/hr),  
 
*''f''' is the design infiltration rate (mm/hr),  
 
*''P'' is the perimeter of the practice (m), and
 
*''P'' is the perimeter of the practice (m), and
*''d'' is the total depth of the practice, including the ponding zone (m).}}
+
*''d<sub>T</sub>'' is the total depth of the practice, including the ponding zone (m).}}
  
 
===Groundwater mounding===
 
===Groundwater mounding===
Line 98: Line 109:
 
Note that this is a minor adaptation (metric units and formatting) from the original tool, written and [https://pubs.usgs.gov/sir/2010/5102/ hosted by the USGS].
 
Note that this is a minor adaptation (metric units and formatting) from the original tool, written and [https://pubs.usgs.gov/sir/2010/5102/ hosted by the USGS].
 
</poem>
 
</poem>
 +
----

Revision as of 18:58, 25 June 2019

This article is specific to bioretention, vegetated systems that infiltrate water to the native soil.
If you are designing a planted system which does not infiltrate water, see advice on Planters: Sizing.

The vertical storage zones in a bioretention cell include: ponding, mulch, filter media, choker course, pipe diameter reservoir and the storage reservoir.

Many of the dimensions in a bioretention system can be predetermined according to the function of the component. There is greatest flexibility in the ponding depth and the depth of the storage reservoir beneath the optional underdrain pipe. The order of operations in calculating these dimensions depends on whether an underdrain is desired.

Component Recommended depth (with underdrain pipe) Recommended depth (no underdrain pipe) Typical void ratio (VR)
Ponding (dp) 300 mm See below 1
Mulch 75 ± 25 mm
  • 0.7 for wood based
  • 0.4 for stone
filter media (dm)
  • 300 mm to support turf grass (and accept only rainwater/roof runoff)
  • 600 mm to support flowering perennials and decorative grasses
  • 1000 mm to support trees
  • 0.4 for sandy mix
  • 0.35 for a more loamy mix.
Choker course 100 mm 0.4 typical
Pipe diameter reservoir Is equal to underdrain pipe diameter Not applicable 0.4
Storage reservoir (ds) See below See below 0.4


Calculate the maximum overall depth[edit]

  • Step 1: Determine what the planting needs are and assign appropriate depth of media, using the table above.
  • Step 2: Select an underdrain pipe diameter (typically 100 - 200 mm), assign this as an 'embedding' depth. *Note that this component does not apply if a downstream riser is being used to control an extended saturation zone.
  • Step 3: Calculate the maximum possible storage reservoir depth beneath the pipe (ds, max, mm):

Where:

  • f' = Design infiltration rate (mm/hr), and
  • t = Drainage time (hrs). Check local regulations for drainage time requirements.

Additional step for system without underdrain[edit]

  • Step 4: Determine maximum permissible ponding depth (dp, max):

Where:

  • f' = Design infiltration rate (mm/hr), and
  • 48 = Drainage time of the ponding (hrs)
  • Note that conceptually the drainage of the ponded area is limited by ex-filtration at the base of the practice.
  • Step 5: Sum total depth of bioretention, and compare to available space above water table and bedrock. Adjust if necessary.

Calculate the remaining dimensions[edit]

  • Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
  • Step 7: Calculate the required total storage (ST, m3):

Where:

  • RVCT is the Runoff volume control target (mm),
  • Ac is the catchment area (Ha), and
  • 10 is the units correction between m3 and mm.Ha.

Additional calculations[edit]

Calculating infiltration practice drainage in 1 dimension[edit]

This spreadsheet compares drainage in a single dimension under zero head conditions, mean head conditions and falling head conditions. It provides a more conservative measurement of the drainage time for the purposes of groundwater mounding (where a shorter drainage time causes a greater impact).

Download drainage time calculator(.xlsx)

Drainage time (3D)[1][edit]

Two practice areas of 9 m2.
P = 12 m (left), P = 20 m (right)

In some situations, it may be desirable to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration.

Note that narrow, linear bioretention features (or bioswales) drain faster than round or blocky footprint geometries.

  • Begin the drainage time calculation by dividing the area of the practice (Ap) by the perimeter (P).
  • To estimate the time (t) to fully drain the facility:

Where:

  • VR is the void ratio of the media,
  • Ap is the area of the practice (m2),
  • f' is the design infiltration rate (mm/hr),
  • P is the perimeter of the practice (m), and
  • dT is the total depth of the practice, including the ponding zone (m).

Groundwater mounding[edit]

When you wish to model the extent of groundwater mounding beneath an infiltration facility. This tool uses Hantush's derivation (1967).
Download groundwater mounding calculator(.xlsm)
Note that this is a minor adaptation (metric units and formatting) from the original tool, written and hosted by the USGS.


  1. Woods Ballard, B., S. Wilson, H. Udale-Clarke, S. Illman, T. Scott, R. Ahsley, and R. Kellagher. 2016. The SuDS Manual. 5th ed. CIRIA, London.