{|{| class="wikitable"
 +
|+Design parameters for dry ponds <ref>https://www.ontario.ca/document/stormwater-management-planning-and-design-manual/stormwater-management-plan-and-swmp-design</ref>
 +
!Element
 +
!Design Objective
 +
!Criteria
 +
|-
 +
|Drainage Area
 +
|Minimum orifice size (see [[flow control]])
 +
|style="text-align: left|5 Ha (≥10 Ha preferred)
 +
|-
 +
|Treatment Volume
 +
|Provision of appropriate level of protection
 +
|style="text-align: left|See [[#.|below]]
 +
|-
 +
|Active Storage
 +
|Detention
 +
|style="text-align: left|[[Total Suspended solids|Suspended solids]] settling 24 hrs (48 hrs preferred)
 +
|-
 +
|Forebay
 +
|Pre-treatment
 +
|style="text-align: left|
 +
*Minimum depth: 1 m;
 +
*Sized to ensure non-erosive velocities leaving forebay;
 +
|-
 +
|Length-to-Width Ratio
 +
|Maximize flow path and minimize short-circuiting potential
 +
|style="text-align: left|
 +
*Overall: minimum 3:1;
 +
*4:1 preferred
 +
|-
 +
|Depth
 +
|Safety
 +
|style="text-align: left|Maximum 3 m
 +
|-
 +
|Side slopes (See also [[berms]])
 +
|Safety
 +
|style="text-align: left|
 +
*4:1 average
 +
|-
 +
|Inlet
 +
|Avoid clogging/freezing
 +
|style="text-align: left|
 +
*Minimum 450 mm;
 +
*Preferred pipe slope: > 1 %;
 +
*If submerged, obvert 150 mm below expected maximum ice depth
 +
|-
 +
|Outlet (See also [[flow control]])
 +
|Avoid clogging/freezing
 +
|style="text-align: left|
 +
*Minimum: 450 mm outlet pipe;
 +
*Preferred pipe slope: > 1 %;
 +
*If orifice control used, 75 mm diameter minimum;
 +
*Minimum 100 mm orifice preferable
 +
|-
 +
|Maintenance access
 +
|Access for backhoes or dredging equipment
 +
|style="text-align: left|
 +
*Provided to approval of Municipality;
 +
*Provision of maintenance drawdown pipe preferred
 +
|-
 +
|Buffer
 +
|Safety
 +
|style="text-align: left|Minimum 3 m above maximum water quality/erosion control water level
 +
|}
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
 +
    
The bottom of a dry pond should be flat to encourage uniform ponding and infiltration across the entire surface. Recommended tolerance on base levels 10 mm in 3m.  
 